Re: Doubt about timeout between nodes of cluster

  • From: Riyaj Shamsudeen <riyaj.shamsudeen@xxxxxxxxx>
  • To: waldirio@xxxxxxxxx
  • Date: Thu, 12 Jun 2008 10:31:28 -0500

Hello Waldirio
>> the time to the first machine detect the second machine powered off is very big (between 1 and 2 min), How are you measuring this time? Are you checking alert log or are you using DB connections to check it?
  Can you also send crsd.log?
Further, refer $CRS_HOME/bin/racgvip and there are few parameters such as check interval, restart attempts etc controlling behavior of VIP failover too. Not sure, they are applicable when machine is rebooted since heartbeat will fail before vip check..

Cheers
Riyaj Shamsudeen
The Pythian Group www.pythian.com
Personal blog: orainternals.wordpress.com

Waldirio Manhães Pinheiro wrote:
   Hello Friends
I'd like to ask about Oracle RAC in Linux environment. I installed two machine with RedHat AS 4Up5 and Oracle 10.2.0.3 <http://10.2.0.3/> with ClusterWare. The installation finish with successful and the data base work fine. I checked my environment of availability with the test below: Station cambeba UP
Station cangua UP
# crs_stat -t Name Type Target State Host
------------------------------------------------------------
ora....BA.lsnr application    ONLINE    ONLINE    cambeba
ora....eba.gsd application    ONLINE    ONLINE    cambeba
ora....eba.ons application    ONLINE    ONLINE    cambeba
ora....eba.vip application    ONLINE    ONLINE    cambeba
ora....UA.lsnr application    ONLINE    ONLINE    cangua
ora.cangua.gsd application    ONLINE    ONLINE    cangua
ora.cangua.ons application    ONLINE    ONLINE    cangua
ora.cangua.vip application    ONLINE    ONLINE    cangua
ora.ora10gq.db application    ONLINE    ONLINE    cangua
ora....q1.inst application    ONLINE    ONLINE    cangua
ora....q2.inst application    ONLINE    ONLINE    cambeba
At this point, that's ok, but when I force a power off in cangua or cambeba (the name of my machines), the time to the firt machine detect the second machine powered off is very big (between 1 and 2 min), so, if my client was working, will lost the query for time out. I changed the configurations in objects ora.cambeba.vip and ora.cangua.vip, but without successful. Any Ideia to fix this problem (decrease the time of check between nodes on cluster) ?!?! PS: I checked in list database, but without successful about this problem

Thanks in advanced.
--
______________
Atenciosamente
Waldirio
msn: wmp@xxxxxxxxxxxxx <mailto:wmp@xxxxxxxxxxxxx>
Site: www.waldirio.com.br <http://www.waldirio.com.br/>
Blog: blog.waldirio.com.br <http://blog.waldirio.com.br/>
PGP: www.waldirio.com.br/public.html <http://www.waldirio.com.br/public.html>

--
//www.freelists.org/webpage/oracle-l


Other related posts: