I believe that the seat for Nitrile and Viton balls should be angled at
45 degrees and not flat i.e. the ball seats in a 'cone' The ball for
injector clacks are usually given a bit more lift than those for a
mechanical pump.
John
The Sheppard Residence wrote:
> I'm finding out lots about Nitrile and Viton balls, but still don't have
> working clacks. They either seal totally (and won't let the injector
> water through) or fail to seal!
>
> More details later, in the mean time -
>
> What is the recommended minimum ball lift on a clack.
>
> Cheers
>
> Peter
>