Hi chaps,
I've recently acquired another 5" gauge tank loco, which with a little bit of
work, could be made into a runner. The engine has two injectors, but no hand
pump or axle pump.
Now injectors being what they are (fussy, especially on a tank loco on a warm
day), I want to add a hand pump as a back-up. The boiler has only two clacks
(one for each injector) and I don't want to give up an injector for the sake of
the hand pump.
What I intend to do is to fit a tee into one of the delivery pipes and connect
the hand pump to that, with the injector feeding straight through and the hand
pump delivering into the leg of the tee. I will of course have to fit a
non-return valve to the delivery end of the injector.
Can anyone see a problem with this arrangement?
Regards