[juneau-lug] Re: Other power outage problems
- From: Nels Tomlinson <nelstomlinson@xxxxxxx>
- To: juneau-lug@xxxxxxxxxxxxx
- Date: Tue, 03 Jun 2003 18:23:07 -0800
You know, that's an interesting thought. I hadn't been thinking along
those lines, since the cpu and chipset fans are both two wire (so, I
think, no rotation sensor). The chipset fan died, won't start at all.
I'll try throwing a spare on that and see if it helps. I'll need to
put it on anyway, after all!
Thanks,
Nels
Myron Davis wrote:
>Hi Nels!
>Some of those athlon boards have fan sensors hooked up to them, so if
>the motherboard detects no fan running it will immediately shutdown.
>The behavior it is exhibiting matches exactly that phenomenom.
>
>Try verifying the fan sensor sometimes if your CPU fan is not plugged into
>sensor 1 this problem will occur as well.
>
>-Myron
>
>On Mon, 02 Jun 2003, Nels Tomlinson wrote:
>
>
>
>>Hi, all,
>>
>>I'm just now getting around to dealing with the backlog of email
>>resulting from that last power outage.
>>
>>When I tried to turn on my main machine after the outage, I found that
>>it will light up all the lights, spin up the fans, and proceed normally
>>for about five seconds. Then the power supply shuts down. I thought that
>>there was a problem with the momentary contact switch which controls
>>power through the motherboard, so I removed it and turned on the power
>>with a screwdriver to the motherboard (obviously, it's an ATX power
>>supply). Same results.
>>
>>Has anyone seen anything like this before? Does anyone have a power
>>supply suited to an Athlon (300 to 400 Watts), for trouble-shooting?
>>
>>Thanks,
>>Nels
>>
>>
>>------------------------------------
>>This is the Juneau-LUG mailing list.
>>To unsubscribe, send an e-mail to juneau-lug-request@xxxxxxxxxxxxx with the
>>word unsubscribe in the subject header.
>>
>>
>
>-- Attached file included as plaintext by Ecartis --
>
>-----BEGIN PGP SIGNATURE-----
>Version: GnuPG v1.0.6 (GNU/Linux)
>Comment: For info see http://www.gnupg.org
>
>iD8DBQE+3NtvnfM/KCuG6/IRAnIxAJ4u0wCb9kfZA13H/3uJ/X1vyC4JxQCfSIeo
>FTEuv4wJqpi8dt5NiOSc0Sw=
>=bUne
>-----END PGP SIGNATURE-----
>
>
>
>------------------------------------
>This is the Juneau-LUG mailing list.
>To unsubscribe, send an e-mail to juneau-lug-request@xxxxxxxxxxxxx with the
>word unsubscribe in the subject header.
>
>
>
------------------------------------
This is the Juneau-LUG mailing list.
To unsubscribe, send an e-mail to juneau-lug-request@xxxxxxxxxxxxx with the
word unsubscribe in the subject header.
- References:
- [juneau-lug] Other power outage problems
- From: Nels Tomlinson
- [juneau-lug] Re: Other power outage problems
- From: Myron Davis
Other related posts:
- » [juneau-lug] Other power outage problems
- » [juneau-lug] Re: Other power outage problems
- » [juneau-lug] Re: Other power outage problems
- » [juneau-lug] Re: Other power outage problems
- [juneau-lug] Other power outage problems
- From: Nels Tomlinson
- [juneau-lug] Re: Other power outage problems
- From: Myron Davis