Feras,

 

Your proposal may be simple but the implications are not.  Before we spend
the committee's time debating and defining syntax, we need to be sure that
the time will be well spent.  The explanation of the problem to be solved
makes sense, but there's no indication that model makers are hampered by
the lack of this functionality, or would be willing to create models with
this syntax if it were to be approved.

 

Thus, at the moment, this appears to be something Cadence thinks would be
a good idea, with no independent verification of need.  I think it's
prudent to table the discussion until actual need is established.

 

Todd.

 

Description: cid:EAFF2D52-4B63-4A05-9D24-B96BE375B7E0@eau.wi.charter.com



Todd Westerhoff

VP, Software Products

 

Signal Integrity Software Inc. .  <http://www.sisoft.com/> www.sisoft.com

6 Clock Tower Place . Suite 250 . Maynard, MA 01754

(978) 461-0449 x24  .   <mailto:twesterh@xxxxxxxxxx> twesterh@xxxxxxxxxx

 

 

"Three in the morning and I'm still awake,
So I picked up a pen and a page . "

                                             -Sidewalk Prophets

 

From: ibis-macro-bounce@xxxxxxxxxxxxx
[mailto:ibis-macro-bounce@xxxxxxxxxxxxx] On Behalf Of Feras Al-Hawari
Sent: Tuesday, March 06, 2012 9:39 AM
To: wkatz@xxxxxxxxxx; james.zhou@xxxxxxxxxx; 'IBIS-ATM'
Subject: [ibis-macro] Re: Updates to BIRD 145

 

Walter,

 

Again you are mixing our simple proposal with other issues or
misunderstandings. Our proposal (direct call of [Model] and cascading
[Model] with [External Circuit]) is a slight enhancement to what is
already there in IBIS i.e., [External Circuit] . We also believe that
there is no need for an IC vendor to proceed with the evaluation of this
proposal, as there are many qualified and experienced people in the ATM
committee to do so.

 

Feras

 

From: Walter Katz [mailto:wkatz@xxxxxxxxxx] 
Sent: Monday, March 05, 2012 11:20 PM
To: james.zhou@xxxxxxxxxx; Feras Al-Hawari; 'IBIS-ATM'
Subject: RE: [ibis-macro] Re: Updates to BIRD 145

 

All,

 

My general comment to BIRD 145 is that it attempts to handle on-die power
in a confusing and awkward way. I would like some imput from IC Vendors on
what problem they are trying to solve, not how one EDA vendor addresses
the problem. So I think any discussion on BIRD 145 should wait until there
is at lease one IC Vendor supporter, and the IC Vendor describes the
problem he is trying to solve.

 

Walter

 

From: ibis-macro-bounce@xxxxxxxxxxxxx
[mailto:ibis-macro-bounce@xxxxxxxxxxxxx] On Behalf Of James Zhou
Sent: Monday, March 05, 2012 8:57 PM
To: Feras Al-Hawari; 'IBIS-ATM'
Subject: [ibis-macro] Re: Updates to BIRD 145

 

Hi Feras, 

 

in BIRD145, example 1:

[Circuit Call] RDL_Interconnect   | Instantiates [External Circuit] named

|                                   "RDL_Interconnect"

| mapping  port        pad/node

Port_map   vcc           18       | Port to implicit pad connection

Port_map   gnd           12       | Port to implicit pad connection

 

What are the rules to map pad/node to pins? In this example, the die pads
have the same name as the pin names. However, in a general cases (such as
the one shown in IBIS 5.0 page 136-138,) the die pads and pins have
different names. This applies to both BIRD 145 and IBIS 5.0. 

 

Also when it involves power ground pins, the mapping from die pads to pins
are almost never 1 to 1 and how does IBIS or  BIRD 145 address this issue?

 

Regards,

James Zhou

QLogic Corp.

 

 

From: Feras Al-Hawari [mailto:feras@xxxxxxxxxxx] 
Sent: Monday, March 05, 2012 2:44 PM
To: James Zhou; 'IBIS-ATM'
Subject: RE: Updates to BIRD 145

 

Hello James,

 

Both cases could be handled in a more accurate manner  if the simulator
supports BIRD 98 and the I/O model contains the KSSO tables. Based on
that, the simulator would scale the IV curves according to the reference
voltage variations (deviations). 

 

Best regards,

 

Feras

 

From: James Zhou [mailto:james.zhou@xxxxxxxxxx] 
Sent: Monday, March 05, 2012 5:21 PM
To: Feras Al-Hawari; 'IBIS-ATM'
Subject: RE: Updates to BIRD 145

 

Hi Feras,

 

I have a couple of questions about this BIRD. 

 

Using the following IBIS keywords and values as an example:

--------------------------------------------------------------------------
-------------------------

[Voltage Range]             1.5000V             1.4250V
1.5750V

[Pullup Reference]          1.5000V             1.4250V
1.5750V

[Temperature Range]        50.0               120.0               -40.0

[Pulldown]

|       Voltage            I(typ)             I(min)             I(max)

     -1.50000000E+0    -16.49945000E-3    -12.54515100E-3
-17.87071600E-3

     -1.42500000E+0    -17.26897000E-3    -13.59391400E-3
-18.38734400E-3

......

--------------------------------------------------------------------------
-------------------------

 

Suppose the user has selected the typical case for simulation,
corresponding to voltage = 1.5000V, temperature = 50.0. 

 

For case a) in your email: if an external circuit is inserted between the
external power supply and A_puref, the actual voltage of A_puref can
deviate from 1.5V. As a result the typical V-I curve (which was obtained
for A_puref=1.5000V)  will no longer apply to this simulation. What is the
proposed approach for this situation?

 

For case b) in your email: This BIRD proposes no changes to how the power
supplies are connected to the model when the power nodes are floating.
However, I'd like to enter this question here anyway for the record: what
happens if a user connected the A_puref to a voltage other than 1.5000V
(such as 1.52385V) and selected  the typical V-I curve ? Further, what if
the user composes a power circuit outside of IBIS and connects it to the
A_puref pins in the EDA tool?

 

This BIRD presents a format to include power distribution circuits in
IBIS. At the same time it should also clearly articulate how this new
structure and data should be simulated when power supply voltages deviate
from those prescribed values in native IBIS V-I curves. 

 

Thanks,

James Zhou

QLogic Corp.

 

 

 

 

From: ibis-macro-bounce@xxxxxxxxxxxxx
[mailto:ibis-macro-bounce@xxxxxxxxxxxxx] On Behalf Of Feras Al-Hawari
Sent: Monday, March 05, 2012 1:48 PM
To: 'IBIS-ATM'
Subject: [ibis-macro] Updates to BIRD 145

 

I have updated BIRD 145 (will be uploaded soon) to explain whose
responsible for delivering power to the reserved voltage reference nodes
in examples 1 & 2 . The new changes are preceded by **. The bulk of the
changes are as shown below:

 

|*             The pre-defined voltage reference ports (i.e., A_pcref,
A_puref, 

|*             A_pdref, A_gcref) of any [Model] that is called in the
circuit

|*             can be either: a) manually interconnected by the model
developer to the

|*             ports of an [External Circuit] by connecting them to the
same node 

|**            declared by the [Node Declarations] keyword as shown in
example 1 below

|**            (i.e., in this case the model developer needs to guarantee
that the 

|**            [External Circuit] contains the appropriate circuitry to
deliver the

|**            required power to each of the voltage reference ports), or
b) automatically

|**            interconnected "as usual" by the EDA tool to the
corresponding voltage 

|**            sources when those ports are left floating as shown in
example 2

|**            below (i.e., in this case the EDA tool should connect the
reserved

|**            voltage reference ports to DC voltage sources with voltage
values

|**            equal to the corresponding reference voltage values in the
[Model]).

 

Feras

 

 

 

  _____  

This message and any attached documents contain information from QLogic
Corporation or its wholly-owned subsidiaries that may be confidential. If
you are not the intended recipient, you may not read, copy, distribute, or
use this information. If you have received this transmission in error,
please notify the sender immediately by reply e-mail and then delete this
message.

 

  _____  

This message and any attached documents contain information from QLogic
Corporation or its wholly-owned subsidiaries that may be confidential. If
you are not the intended recipient, you may not read, copy, distribute, or
use this information. If you have received this transmission in error,
please notify the sender immediately by reply e-mail and then delete this
message.

GIF image

Other related posts: