Johan,
In Germany we have certainly much more than 100 interfaces to S7 with
Profibus DP; connected to Micro I/A and CP60 with FBM 223.
It is a very well running connection, need however attention for the
engineering and sizing.
I recommend to contact your Foxboro sales/engineering guys, they can =
assist
you.
Regards
Heinz Maurer
Vertriebsbuero Duesseldorf
Invensys Systems GmbH
Heerdter Lohweg 53-55
40549 Duesseldorf
Germany
Tel.: +49 (0) 211 5966 -333
Fax.: +49 (0) 211 5966 -300
Mob.: +49 (0) 173 25 32 515
Email: heinz.maurer@xxxxxxxxxxxx
http
-----Urspr=FCngliche Nachricht-----
Von: Johan.Van.Elsen@xxxxxxxxxx [mailto:Johan.Van.Elsen@xxxxxxxxxx]=20
Gesendet: Donnerstag, 28. August 2003 17:14
An: foxboro@xxxxxxxxxxxxx
Betreff: [foxboro] connecting Foxboro I/A with Simatic S7
Dear Users,
As many customers whe are upgrading our Simatic S5 PLC's to the newer =
S7
ones. Our communication with S5 and the I/A system is based on the =
Modbus
communication, and we are now searching for some other solutions to =
connect
with the S7 PLC's.
Has someone experience with:
AW70/OPC IO Gate and Simatic/OPC server
AW70 and Simatic H1/Interface
the new CP60 and profibus FBM (or other FBM's)
What is the reliability of these communications
Thanks,
Johan Van Elsen
Systeembeheerder
INDAVER nv
E-mail: Johan.van.elsen@xxxxxxxxxx
Tel : + 32 (0)3 / 568-48-65
Fax: + 32 (0)3 / 568-49-99
=20
=20
_______________________________________________________________________
This mailing list is neither sponsored nor endorsed by Invensys Process
Systems (formerly The Foxboro Company). Use the info you obtain here at =
your
own risks. Read http://www.thecassandraproject.org/disclaimer.html
=20
foxboro mailing list: http://www.freelists.org/list/foxboro
to subscribe: =
mailto:foxboro-request@xxxxxxxxxxxxx?subject=3Djoin
to unsubscribe: =
mailto:foxboro-request@xxxxxxxxxxxxx?subject=3Dleave
=20
_______________________________________________________________________
This mailing list is neither sponsored nor endorsed by Invensys Process
Systems (formerly The Foxboro Company). Use the info you obtain here at
your own risks. Read http://www.thecassandraproject.org/disclaimer.html
foxboro mailing list: http://www.freelists.org/list/foxboro
to subscribe: mailto:foxboro-request@xxxxxxxxxxxxx?subject=join
to unsubscribe: mailto:foxboro-request@xxxxxxxxxxxxx?subject=leave
Other related posts:
- » [foxboro] AW: connecting Foxboro I/A with Simatic S7