[argyllcms] Re: Scainin problem
- From: "ronn kling" <ronn@xxxxxxxxxxx>
- To: <argyllcms@xxxxxxxxxxxxx>
- Date: Mon, 09 Jun 2008 07:34:07 -0400
OK, thanks and here it is
I created this using the logo2cats from the original and then the spec2cie
function.
Ronn Kling
----- Original Message -----
From: "Graeme Gill" <graeme@xxxxxxxxxxxxx>
To: <argyllcms@xxxxxxxxxxxxx>
Sent: Monday, June 09, 2008 7:18 AM
Subject: [argyllcms] Re: Scainin problem
ronn kling wrote:
I am new to argyll and color managment in general so I apologize for this
basic usage question.
When I run scanin I get a .ti3 file with no data. The command I use is
scanin -v -dipn cropped.tif "ColorCheckerSG.cht" "Digital ColorChecker
SG.cie"
The diagnostic image shows perfect matching with the outlines and the
image, but I get a series of warning messages.
Warning: Couldn't match field '01'
...
...
Warning: Couldn't match field '140'
Sounds like the reference file doesn't match the cie file. Either the
patch
names don't match, or the one of the column headings are wrongly labeled.
You'd have to send me the cie file for me to make a more specific
diagnosis.
Graeme Gill.
- Follow-Ups:
- [argyllcms] Re: Scainin problem
- From: Graeme Gill
- References:
- [argyllcms] Scainin problem
- From: ronn kling
- [argyllcms] Re: Scainin problem
- From: Graeme Gill
Other related posts:
- » [argyllcms] Scainin problem
- » [argyllcms] Re: Scainin problem
- » [argyllcms] Re: Scainin problem
- » [argyllcms] Re: Scainin problem
ronn kling wrote:
I am new to argyll and color managment in general so I apologize for this basic usage question. When I run scanin I get a .ti3 file with no data. The command I use is scanin -v -dipn cropped.tif "ColorCheckerSG.cht" "Digital ColorChecker SG.cie"The diagnostic image shows perfect matching with the outlines and the image, but I get a series of warning messages.Warning: Couldn't match field '01' ... ... Warning: Couldn't match field '140'
Sounds like the reference file doesn't match the cie file. Either the patch
names don't match, or the one of the column headings are wrongly labeled.You'd have to send me the cie file for me to make a more specific diagnosis.