[argyllcms] Re: Question about DeltaE from printread and one about iccexamin/profcheck

On 9/11/07, Kai-Uwe Behrmann <> wrote:

> Indeed, I looked at some available samples from other profiling packages,
> like PM and L-Prof, and found, the RGB 0...255 range where used for
> obvious reasons. As well the #17 draft speaks explicitely about that range
> for RGB. Did you run a different profiling package with argyll's
> measurements, for instance L-Prof?
> Nethertheless a exception to argyll measurements should fix this
> difference.
>
> Gerhard and Lars,
> thanks for pointing out this case.

Thanks to all for figuring out the scaling issue in iccexamin. It
works nice now after I have massaged the data with awk.

Kai-Uwe if you need some files for debugging iccexamin I have uploaded
all files related to this target here.


http://www.mulebakken.net/div/test4.tgz

Lars Tore Gustavsen

Other related posts: