On Thu, Jan 21, 2010 at 11:31 AM, Alastair M. Robinson
<profiling@xxxxxxxxxxxxxxxxxxxxxxx> wrote:
> Hi :)
>
> Pedro Côrte-Real wrote:
>
>> Profile check complete, errors: max. = 144.994340, avg. = 76.584552,
>> RMS = 79.919560
>>
>> I have no idea how to interpret it though. Is the error too high?
>
> *Way* too high - are you absolutely sure you compared the right .ti3 with
> the profile?
>
> Typically you'd expect to see a max error of below 10dE and if you're lucky,
> round about 2 or 3, and the average should be under 3, hopefully nearer 1.
>
> If you did compare the correct .ti3 file and profile, then chances are you
> had some (many!) bad readings on the chart, so try reading it again and keep
> an eye out for any error messages or warnings.

I don't think there were any error messages when reading and I do
think I compared the correct .ti3 file. Could be that the 1.1.0RC1
version had some bug that I am hitting here.