[argyllcms] Re: Monitor profile

> Leave this running, and on another terminal session, run spot read
> 
> spotread -yl -a
> 
> and read the white. Does it agree with what dispcal was targeting ?

This is with a DTP94:

 Result is XYZ: 92.250000 97.750000 89.650000,
              D50 Lab: 99.123392 -3.536049 -7.138165

 Ambient = 307.1 Lux, CCT = 5610K
 Closest Planckian temperature = 5420K
 Closest Daylight temperature  = 5534K

This is far from my command line target white:

> dispcal -v -c1 -m -qh -gl -yl -t5000 Eizo_i1

Roger Breton 
Just a regular guy?



Other related posts: