[argyllcms] Re: DeviceLink Profile refining
- From: Klaus Karcher <lists@xxxxxxxxxxxxxxxxx>
- To: argyllcms@xxxxxxxxxxxxx
- Date: Mon, 12 Feb 2007 19:22:51 +0100
marcel nita wrote:
I have attached a few measurements.
In the archive ProofingPaper.zip you can find 2 measurement files.
Index 0 means that it was the initial target.
In PremiumGlossyPhoto.zip there are 5 measurement files. As you will
see, with this paper only on step 4 the substrate dE started to
increase.
I just took a look at the substrate values and saw what I guessed
yesterday: both substrates are a little bit to dark for ISO Coated. Your
substrates are round about Delta L = 1 darker than the paper you try to
emulate. What you see in the second set of measurement files is just
noise: in all cases the paper is emulated with only 0.4% Magenta --
refine can't and won't change anything: the Delta E cant fall below
about 1 (until you use another substrate or white ink to print ;-) --
but that's ok. Also the average and max DE for "PremiumGlossyPhoto" is
not bad. Refine did a good job IMO. If you also get a good visual match
and smooth gradients there is nothing to complain about. Maybe the
PremiumGlossyPhoto (I guess it's the one from Epson?) contains too much
optical brighteners to get a good visual match in some viewing conditions.
BTW: do you know that ISO Coated is outdated and shold be replaced by
ISO Coated v2 until April?
The new reference Data (FOGRA39) can be downloaded from
http://www.color.org/FOGRA39.html
Additional Information about it can be found here:
http://www.fogra.org/rss/blog0033.html
And here you get the new ECI Profiles: http://eci.org/eci/en/
http://eci.org/eci/downloads/ECI-en/icc_profiles_from_eci/ECI_Offset_2007.zip
Regards, Klaus
- References:
- [argyllcms] Re: DeviceLink Profile refining
- From: marcel nita
- [argyllcms] Re: DeviceLink Profile refining
- From: Gerhard Fuernkranz
- [argyllcms] Re: DeviceLink Profile refining
- From: marcel nita
- [argyllcms] Re: DeviceLink Profile refining
- From: Graeme Gill
- [argyllcms] Re: DeviceLink Profile refining
- From: marcel nita
Other related posts:
- » [argyllcms] DeviceLink Profile refining
- » [argyllcms] Re: DeviceLink Profile refining
- » [argyllcms] Re: DeviceLink Profile refining
- » [argyllcms] Re: DeviceLink Profile refining
- » [argyllcms] Re: DeviceLink Profile refining
- » [argyllcms] Re: DeviceLink Profile refining
- » [argyllcms] Re: DeviceLink Profile refining
- » [argyllcms] Re: DeviceLink Profile refining
- » [argyllcms] Re: DeviceLink Profile refining
- » [argyllcms] Re: DeviceLink Profile refining
- » [argyllcms] Re: DeviceLink Profile refining
- » [argyllcms] Re: DeviceLink Profile refining
- » [argyllcms] Re: DeviceLink Profile refining
- » [argyllcms] Re: DeviceLink Profile refining
- » [argyllcms] Re: DeviceLink Profile refining
I have attached a few measurements. In the archive ProofingPaper.zip you can find 2 measurement files. Index 0 means that it was the initial target. In PremiumGlossyPhoto.zip there are 5 measurement files. As you will see, with this paper only on step 4 the substrate dE started to increase.
- [argyllcms] Re: DeviceLink Profile refining
- From: marcel nita
- [argyllcms] Re: DeviceLink Profile refining
- From: Gerhard Fuernkranz
- [argyllcms] Re: DeviceLink Profile refining
- From: marcel nita
- [argyllcms] Re: DeviceLink Profile refining
- From: Graeme Gill
- [argyllcms] Re: DeviceLink Profile refining
- From: marcel nita