[argyllcms] Re: Device link gamut mapping: how to do it right?
- From: "Alastair M. Robinson" <profiling@xxxxxxxxxxxxxxxxxxxxxxx>
- To: argyllcms@xxxxxxxxxxxxx
- Date: Sun, 07 Sep 2008 11:27:46 +0100
Hi :)
Nikolay Pokhilchenko wrote:
1. tiffgamut.exe -ir -pj -cpcd AdobeRGB1998.icc Shot.tif
why -ir, not -ia?
Just a mistake on my part when changing from 0.7b8 syntax ( -ij) to
1.0.0 syntax (-i<intent> -pj).
I shall change this for the next version, unless people would prefer it
to be runtime-selectable?
2. collink -G Shot.gam -ip -op -ip -cmt -dpp AdobeRGB1998.icc HPED2880.icc
Shot_lnk.icc
why two -ip?
Another oversight on my part ;)
As I understood from the CMS documentation, in gamut maping mode the -o key
isn't used at all, as it for simple mode exclusively IMHO. Am I right? There is
clear division between simple and gamut mapping modes in colllink.htm.
Scar tissue left over from early experiments - you're correct, it should
be removed :)
So the questions: which intent I need to chose in tiffgmut?
I'd say use a unless you have a specific reason not to.
And is there the -o key needed in collink gamut mapping mode?
No, and the next version of ImgTarget will clean up these issues -
thanks for pointing them out :)
All the best,
--
Alastair M. Robinson
- References:
- [argyllcms] Device link gamut mapping: how to do it right?
- From: Nikolay Pokhilchenko
Other related posts:
- » [argyllcms] Device link gamut mapping: how to do it right?
- » [argyllcms] Re: Device link gamut mapping: how to do it right?
- » [argyllcms] Re: Device link gamut mapping: how to do it right?
- » [argyllcms] Re: Device link gamut mapping: how to do it right?
- » [argyllcms] Re: Device link gamut mapping: how to do it right?
- » [argyllcms] Re: Device link gamut mapping: how to do it right?
- » [argyllcms] Re: Device link gamut mapping: how to do it right?
- » [argyllcms] Re: Device link gamut mapping: how to do it right?
- » [argyllcms] Re: Device link gamut mapping: how to do it right?
- » [argyllcms] Re: Device link gamut mapping: how to do it right?
1. tiffgamut.exe -ir -pj -cpcd AdobeRGB1998.icc Shot.tif why -ir, not -ia?
2. collink -G Shot.gam -ip -op -ip -cmt -dpp AdobeRGB1998.icc HPED2880.icc Shot_lnk.icc why two -ip?
As I understood from the CMS documentation, in gamut maping mode the -o key isn't used at all, as it for simple mode exclusively IMHO. Am I right? There is clear division between simple and gamut mapping modes in colllink.htm.
So the questions: which intent I need to chose in tiffgmut?
And is there the -o key needed in collink gamut mapping mode?
- [argyllcms] Device link gamut mapping: how to do it right?
- From: Nikolay Pokhilchenko