[argyllcms] Re: Bug in 1.1.0 RC1
- From: Graeme Gill <graeme@xxxxxxxxxxxxx>
- To: argyllcms@xxxxxxxxxxxxx
- Date: Tue, 10 Nov 2009 01:44:46 +1100
David Garabana Barro wrote:
david@maquina:~/Argyll_V1.1.0_RC1/bin$ ./dispcal -v -R -yc -p 0.5,0.5,1.0
XRandR 1.2 is faulty - falling back to older extensions
Setting up the instrument
Need emissive measurement capability,
but instrument doesn't support it
dispcal: Error - new_disprd() failed with 'Instrument Access Failed'
Sorry, I commandeered the -p option to support projector
measurement (ColorMunki) in V1.1.0, so setting the test
window now uses the -P option.
Graeme Gill
Other related posts: