[argyllcms] Black point powell failed
- From: Stefan Heinsen <sheinsen@xxxxxxxxxxxxxxxxx>
- To: argyllcms@xxxxxxxxxxxxx
- Date: Fri, 30 Jun 2006 12:29:41 +0200
Hi,
im having a problem with profile. Depending on the
measuredata profile fails with
"./profile: Error - set_icxLuLut: Black point powell failed"
in xlut.c line 3563.
I tried to debug the problem but failed to understand the
code. The function powell returns -0.95.
This happens on a Canon W8400 that can produce extremely
dark black. With 100% black ink only i get a Lab Value of
2.297 3.558 -3.788 and with mixed CMYK black (all inks at
100%) its possible to get a Lab of 0.474 0.012 -0.059.
Maybe this has something to do with it.
Any ideas?
Stefan
- Follow-Ups:
- [argyllcms] Re: Black point powell failed
- From: Gerhard Fuernkranz
Other related posts:
- » [argyllcms] Black point powell failed
- » [argyllcms] Re: Black point powell failed
- » [argyllcms] Re: Black point powell failed
- [argyllcms] Re: Black point powell failed
- From: Gerhard Fuernkranz