This message was posted by Hugo Torbidoni on AmayaUsers.com. PLEASE DO NOT REPLY VIA EMAIL. Instead, respond to the thread on the WEBSITE by clicking here: http://www.amayausers.com/boards/ultimatebb.php?/topic/6/169.html#000003 Have you checked whether the cap frame(s) are secure in the driver? Are the 3 latches that hold the frame to the driver secure? The driver has a steel cable that wraps around the outside of the round portion of the driver.Is it clamped securely? Be careful when adjusting the feeder assembly. Any adjustment to this gear must be made so that the needle case can move from #1 to #16 with out interference. Is the problem area close to the bottom or top of the design? Hugo Torbidoni Melco Tech 301-471-3157 =========================================================== The AmayaUsers Mailing List Website: http://www.amayausers.com Discussion Board: http://www.amayausers.com/boards Subscribe/Unsubscribe: http://www.amayausers.com/list ===========================================================