[SI-LIST] Re: IBIS basic question

  • From: "Mike LaBonte" <milabont@xxxxxxxxx>
  • To: <si-list@xxxxxxxxxxxxx>
  • Date: Thu, 2 Dec 2004 10:39:02 -0500
Jing,

If the various IBIS I/V curves have currents in overlapping voltage ranges
those currents will be summed, at least in simulators that I am familiar
with. The proper technique of producing IBIS models, however, avoids having
the "same" current in more than one I/V curve. The output transistors are to
be disabled for clamp tests, and clamps are to be disabled for output tests.
Some techniques use subtraction if clamp disabling is not possible. Also,
the power and ground clamp curves are created over non-overlapping voltage
ranges.

Furthermore, best practice is to have the clamp curves fall to zero current
with a flat slope at the "inner" ends, so that when simulators guess the
"missing" data for each clamp curve (they have to make some assumption) they
will not extrapolate non-zero currents from the endpoints and sum those in.
The exception is for buffers with built-in termination, which in fact do
have non-zero current between 0V and VCC, but only in one clamp curve.

So the double counting you are asking about is a potential problem that is
to be avoided by careful model construction. For more info there is an IBIS
email list that is the best place to ask IBIS questions. Info below on this.

Mike LaBonte

IBIS email list instructions:
|For help or to subscribe/unsubscribe, email majordomo@xxxxxxx with the 
|appropriate command message(s) in the body:
|
|  help
|  subscribe   ibis       <optional e-mail address, if different>
|  subscribe   ibis-users <optional e-mail address, if different>
|  unsubscribe ibis       <optional e-mail address, if different>
|  unsubscribe ibis-users <optional e-mail address, if different>
|
|or email a request to ibis-request@xxxxxxxx
|
|IBIS reflector archives exist under:
|
|  http://www.eda.org/pub/ibis/email_archive/  Recent  
| http://www.eda.org/pub/ibis/users_archive/  Recent
|  http://www.eda.org/pub/ibis/email/          E-mail since 1993 

-----Original Message-----
From: si-list-bounce@xxxxxxxxxxxxx [mailto:si-list-bounce@xxxxxxxxxxxxx] On
Behalf Of Jing Wu
Sent: Wednesday, December 01, 2004 7:59 PM
To: si-list@xxxxxxxxxxxxx
Subject: [SI-LIST] IBIS basic question

Hi, ibis experts:

    For  the GND clamp I-V curve, normally the data is taken from -Vcc to
Vcc while for the power clamp I-V curve, the data is taken from Vcc to 2Vcc.
How about if both the GND clamp and Power Clamp curve have the
data from    - Vcc to 2Vcc, will the simulator double-count the data or
different simulator have different solutions? =20

Thanks,
jing

------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field

or to administer your membership from a web page, go to:
http://www.freelists.org/webpage/si-list

For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field

List FAQ wiki page is located at:
                http://si-list.org/wiki/wiki.pl?Si-List_FAQ

List technical documents are available at:
                http://www.si-list.org

List archives are viewable at:     
                http://www.freelists.org/archives/si-list
or at our remote archives:
                http://groups.yahoo.com/group/si-list/messages
Old (prior to June 6, 2001) list archives are viewable at:
                http://www.qsl.net/wb6tpu
  





[ Home | Signup | Help | Login | Archives | Lists ]

All trademarks and copyrights within the FreeLists archives are owned by their respective owners.
Everything else ©2007 Avenir Technologies, LLC.