[SI-LIST] About IBIS error from IBIS check
- From: "Jack W.C. Lin" <JackWCLin@xxxxxxxxxxxx>
- To: si-list@xxxxxxxxxxxxx
- Date: Wed, 6 Nov 2002 09:48:15 +0800
Hi All SI friends:
Recently, I found many errors such like this from IBIS check:
ERROR - Model [Name]: The [Falling Waveform]
with [R_fixture]=60 Ohms and [V_fixture_min]=3V
has MIN column DC endpoints of 2.23V and 3.00v, but
an equivalent load applied to the model's I-V tables yields
different voltages ( 2.10V and 3.00V),
a difference of 6.44% and 0.00%, respectively.
I don't know why these I-V curves have to apply on "an equivalent load", it
seems a double check of those V-T points. If this happened, how could I
modify it? Any recommands are highly appreciated! Thanks
Jack
------------------------------------------------------------------