- From: Ray Anderson <reanderson@xxxxxxxxxxxxx>
- To: si-list@xxxxxxxxxxxxx
- Date: Tue, 05 Oct 2004 08:33:50 -0700
Steve-
See the Agilent ATF 55143 Reliability Data Sheet (
http://literature.agilent.com/litweb/pdf/5988-4885EN.pdf )
Table 4 (ESD Results) claims Human Body Model Results of 300V (Class1)
and Machine Model Results of 40V (Class A)
-Ray Anderson
Charlie Anderson wrote:
>I was interested in this question so I looked up the data sheets on both
>devices.
>
>The ATF-55143 can handle ESD strikes up to 200V (HBM) while the CM1213
>starts conducting at +/-9V for ESD strikes to 8kV(HBM). I'd think you
>are covered with that combination.
>
>Regards,
>Charlie Anderson
>Sr. Electrical Engineer
>Micro Control Company
>(763) 277-9244
>c.anderson@xxxxxxxxxxxxxxxx
>
>
>
.
------------------------------------------------------------------