[si-list]
||
[Date Prev]
[10-2002 Date Index]
[Date Next]
||
[Thread Prev]
[10-2002 Thread Index]
[Thread Next]
[SI-LIST] Re: AC Waveform question
- From: "Zabinski, Patrick J." <zabinski.patrick@xxxxxxxx>
- To: si-list@xxxxxxxxxxxxx
- Date: Mon, 7 Oct 2002 11:09:30 -0500
Doug,
Is your meter set to "AC Volts" or "DC Volts"?
My understanding is that "AC Volts" on a meter will
measure the RMS value, while the "DC Volts" setting
will measure the average value.
Pat
>
> Hi all,
>
> I know I must have learned this in school, but now I'm not
> sure of the answer!
>
> Assume I have a full-wave rectified sine wave of low
> frequency. Assume the
> magnitude is 1.0 Volt peak (zero to peak). Assume I apply
> this wave form
> across an ordinary 1 Volt analog meter. What does the meter read?
> The RMS value (.707 Volts) or
> The average value (.636 Volts)
>
> Doug
>
------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field
or to administer your membership from a web page, go to:
http://www.freelists.org/webpage/si-list
For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field
List archives are viewable at:
http://www.freelists.org/archives/si-list
or at our remote archives:
http://groups.yahoo.com/group/si-list/messages
Old (prior to June 6, 2001) list archives are viewable at:
http://www.qsl.net/wb6tpu
|

|