[SI-LIST] differential signals spacing

  • From: Goutham.S@xxxxxxxxxx
  • To: si-list@xxxxxxxxxxxxx
  • Date: Wed, 10 Oct 2001 12:17:54 +0800



Hi All,

In the differential trace routing (ethernet, scsi, USB etc.) , Routing
guidelines mentions that the differential pairs should be routed as close as
possible to
effectively utilise the differential signal properties (Noise Cancellation).
They don't mention the spacing in terms of mils or inches.

We were earlier giving the spacing as per the PCB designer's convenience. The
smallest spacing used is 5mils.
As far as Manufacturering technology is concerned, spacing can be 2.5 mil and
above.

My doubt is that from Electrical Engineers point of view, what is the spacing
requirement for differential signals.

Regards
Goutham Sabavat
Force computers India Pvt Ltd


------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field

or to administer your membership from a web page, go to:
http://www.freelists.org/webpage/si-list

For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field

List archives are viewable at:     
                http://www.freelists.org/archives/si-list
or at our remote archives:
                http://groups.yahoo.com/group/si-list/messages 
Old (prior to June 6, 2001) list archives are viewable at:
                http://www.qsl.net/wb6tpu
  





[ Home | Signup | Help | Login | Archives | Lists ]

All trademarks and copyrights within the FreeLists archives are owned by their respective owners.
Everything else ©2007 Avenir Technologies, LLC.