Hi all,

Which is a better 4 layer stack up configuration?

Signal 1
Ground 
Power 
Signal 2

OR

Signal 1
Ground
Signal 2
Power

It seems like the 2nd option gives us more flux cancellation as a Ground
plane is sandwiched between Signal 1 and Signal 2.

Any comments??