Hi All:
I am trying to simulate a 3 conductor wire environment and extract the
inductance matrix using fasthenry. I am supposed to have a symmetrical and
non-negative matrix. However, I am unable to do that. I might have
mis-used .equiv and .external command.
Suppose these are the end points of each of my conductor:
conductor 1: A, B
conductor 2: C, D
conductor 3: E, F
And they lie in parallel.
Right now I have the following in my fastHenry code:
.external A C
.equiv B D
.external C E
.equiv D F
.external A E
.equiv B F
I might have did something wrong with my setup. Anyone have an idea?
Thanks in advance for your help
Best Regards,
Andy Kuo
------------------------------------------------------------------