The 47CFR68 complient device shall withstand a traverse (pin-to-pin) 9/720 µs
surge of 1 kV
and a longitudinal (pin-to-ground) 10/160 µs surge of 1.5 kV.
In IEC 60603-7-x there are requirements for the RJ-45:
1 kV DC/AC pin-to-pin
1.5 kV DC/AC pin-to-shield
Thomas
------------------------------------------------------------------