Jon as a number of people have pointed out, the electrical and physical
lengths are not very close. Material anisotropy alone causes skew
typically of 3-10ps/inch, ie 2-6% of the run.
Best regards,
Steve.
jon_powell37 wrote:
> When I see these rules to match within 10 mils (or n mils) I wonder who
> much matching is really required in the electrical sims (or other
> assumptions). Because I don't believe that matching physical length is
> the same as matching electrical length. And the router only does
> physical length. So the question is, "how close is electrical length to
> physical length". I would be very suprized if the accuracy can be
> expected to be better than the line width (call it 5 mils).
>
> So, if we are just making a "easy to understand" rule. Fine.
> But if it is a necessary rule. Not fine.
>
> Jon
>
>
>
>
>
> Disclaimer:
> The content of this message is my personal opinion only and although I
> am an employee of Intel, the statements I make here in no way represent
> Intel's position on the issue, nor am I authorized to speak on behalf of
> Intel on this matter.
>
> ------------------------------------------------------------------
> To unsubscribe from si-list:
> si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field
>
> or to administer your membership from a web page, go to:
> http://www.freelists.org/webpage/si-list
>
> For help:
> si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field
>
>
> List technical documents are available at:
> http://www.si-list.net
>
> List archives are viewable at:
> http://www.freelists.org/archives/si-list
> or at our remote archives:
> http://groups.yahoo.com/group/si-list/messages
> Old (prior to June 6, 2001) list archives are viewable at:
> http://www.qsl.net/wb6tpu
>
>
>
>
>
------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field
or to administer your membership from a web page, go to:
http://www.freelists.org/webpage/si-list
For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field
List technical documents are available at:
http://www.si-list.net
List archives are viewable at:
http://www.freelists.org/archives/si-list
or at our remote archives:
http://groups.yahoo.com/group/si-list/messages
Old (prior to June 6, 2001) list archives are viewable at:
http://www.qsl.net/wb6tpu
|

|