[SI-LIST] A Hspice question about current on W-element

  • From: xuzhengrong <Zhengrong.Xu@xxxxxxxxxx>
  • To: si-list@xxxxxxxxxxxxx
  • Date: Mon, 07 Apr 2008 15:55:22 +0800
Hi all,
I recently used Hspice to observe the current on a W-element.

W-element is a four-ports element as a distributed transmission line. 

For example,  

W1  in  gnd_in  out  gnd_out  rlgcfile=w1.rlgc  L=1,  assuming that gnd_in
and gnd_out all connect to 0.

I used .print i1(W1) i2(W1) i3(W1) i4(W1) to observe corresponding i(in)
i(gnd_in) i(out) i(gnd_out).

I(gnd_in) is the return current of i(in), so i(gnd_in) should be the inverse
phase of i(in). The same to i(out) and i(gnd_out).

The simulation results show that i1(W1)= - i2(W1) (as we have expected), but
i3(W1)= i4(W1) surprisingly.

Why is i4(W1) equal to i3(W1) instead of i4(W1)=-i3(W1) in this simulation?

Is anything wrong about my idea?

Appreciate anything about it. 

 

Best Regards,

Zhengrong

 



------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field

or to administer your membership from a web page, go to:
http://www.freelists.org/webpage/si-list

For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field


List technical documents are available at:
                http://www.si-list.net

List archives are viewable at:     
                http://www.freelists.org/archives/si-list
or at our remote archives:
                http://groups.yahoo.com/group/si-list/messages
Old (prior to June 6, 2001) list archives are viewable at:
                http://www.qsl.net/wb6tpu
  





[ Home | Signup | Help | Login | Archives | Lists ]

All trademarks and copyrights within the FreeLists archives are owned by their respective owners.
Everything else ©2007 Avenir Technologies, LLC.