- From: Jeff Seeger <jseeger@xxxxxxxxxxxxxx>
- To: si-list@xxxxxxxxxxxxx
- Date: Thu, 05 Apr 2007 14:46:04 -0400
Andy wrote:
> what is "venting"?
In built-up multilayers, which start with a traditional core
laminate, subsequent dielectrics are applied in liquid or semi-
liquid state. Unbroken copper areas inhibit cure. Relief is
in the form of "vent" pads appearing as stray anti-pads, or as
a cross-hatch shape.
Sorry that carpal tunnel limits my replies. Or maybe that's a
good thing.
Best regards,
--
Jeff Seeger Applied CAD Knowledge Inc