- From: Istvan Novak <istvan.novak@xxxxxxx>
- To: Mark_Burford@xxxxxxxxxxx
- Date: Mon, 07 Feb 2005 08:59:52 -0500
Mark,
Welome to the si-list forum.
In a very simplistic way we can say that the differential impedance
is twice the single-ended impedance because we connect two
transmission lines in series. Series impedances add, similarly
series-connected inductances add. You can use the same
formula of Zo*delay, just have to substitute the correct terms:
differential impedance and differential (odd-mode) delay.
You can find very good tutorials on the subject on the TDA
Systems website. http://www.tdasystems.com/
Regards,
Istvan Novak
SUN Microsystems
Mark Burford wrote:
>Hi guys, just subscribed.
>I understand the inductance of stripline to be Z0*delay_of_line
>Could anyone tell me what the inductance is for differential odd mode
>stripline please? Does it change? I know Z0 for differential stripline
>is near double that of single stripline, but does this affect
>inductance?
>
>Many thanks
>
>Mark Burford
>Mburford AT xyratex DOT com
>
>
>
>
------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field
or to administer your membership from a web page, go to:
http://www.freelists.org/webpage/si-list
For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field
List FAQ wiki page is located at:
http://si-list.org/wiki/wiki.pl?Si-List_FAQ
List technical documents are available at:
http://www.si-list.org
List archives are viewable at:
http://www.freelists.org/archives/si-list
or at our remote archives:
http://groups.yahoo.com/group/si-list/messages
Old (prior to June 6, 2001) list archives are viewable at:
http://www.qsl.net/wb6tpu
|

|