On samedi 05 janvier 2008, Graeme Gill wrote:
> Frédéric Mantegazza wrote:
> > In occurs mostly in the last patches of the sequences, in darks ones.
> > We can see the patch displayed, then, before changing for the next,
> > the patch becomes brighter. Sometimes it a is very small change,
> > sometimes it is a huge change. And sometime, the patch change more
> > than one time.
>
> I got the impression that there problem was two patch colors
> being displayed at the same time ?
>
> It sounds from your description above that the patch value is
> simply changing as part of the calibration. If you run with -v2
> you should see progress information for each patch. Readings
> that don't meet the target tolerance are adjusted and measurements
> repeated until it meets tolerance or there are too many trials
> (ie. the test patch color sequence is not pre-determined but is
> created dynamically). Does the change in patch color correspond
> to each progress report ?
Mike will make more tests...
--
Frédéric
http://www.gbiloba.org